UDP 34962

ProtocolUDP
Port34962
Labels

Synopsis

  • UDP port 34962 is used by PROFINET IO Real-Time (RT) traffic (IANA: profinet-rt) for cyclic I/O data between PLC “IO-Controllers” and field “IO-Devices.”
  • Real-world examples include Siemens SIMATIC S7-1200/S7-1500 PLCs exchanging RT data with ET 200SP/ET 200S I/O over PROFINET.
  • Drives such as Siemens SINAMICS G120/S120 and SEW‑Eurodrive MOVI‑C operate as PROFINET devices communicating with PLCs via UDP 34962.
  • Industrial robots with PROFINET options (e.g., KUKA, ABB) and I/O systems like Phoenix Contact Axioline F or WAGO 750 series also use this port for PROFINET RT data.
  • Many third‑party PROFINET‑capable devices (e.g., Pepperl+Fuchs sensors, Beckhoff PROFINET device terminals) participate in this traffic as well.
  • Security note: ICS advisories have documented denial‑of‑service issues in some PROFINET stacks reachable over this port, so exposing UDP 34962 to untrusted networks has been associated with exploitation attempts.